Keyence Gs-11pc Manual (SIMPLE · Blueprint)

Are you dealing with an , wiring , or troubleshooting0;40a; issue? Do you need to know about compatible safety controllers ? Are you looking to cascade multiple sensors?

The actuator can approach the switch from the front or the sides. Ensure the marked sensing faces match up directly. LED Status Indicators

Industrial safety standards (ISO 13849-1) require periodic testing of interlock devices.

When the GS-11PC encounters an issue, the main multi-color LED provides immediate diagnostic feedback. LED Behavior Potential Cause Action Plan No power supply Check 24 VDC and 0 VDC wiring connection. Flashing Red (1 time) OSSD output fault Check for short circuits between OSSD lines or to 24V/0V. Flashing Red (2 times) OSSD input fault Verify upstream cascaded switches are powered and aligned. Flashing Red (3 times) Actuator error Ensure the correct paired RFID actuator is being used. Flashing Orange Poor alignment Readjust the mechanical gap between switch and actuator. 6. Maintenance and Safety Inspections

| Category | Specification | Detail | | :--- | :--- | :--- | | | Type | Non-contact standard type | | | Cable Specification | M12 connector, 8-pin, 0.3 m length | | | Weight | Approx. 80 g | | | Material | Case: Zinc die cast (Nickel chrome plating) / Cable: PVC | | Electrical | Output Type | PNP | | | Control Output (OSSD) | Transistor outputs × 2 (Max. load current: 150 mA) | | | Auxiliary Output (AUX) | 1 transistor output (Max. load current: 50 mA) | | | Power Supply Voltage | 24 V DC ±20 % (Ripple P-P 10 % or less, Class2) | | | Power Consumption | 0.8 W | | | Residual Voltage (ON) | Max 2.5 V (with a cable length of 5 m) | | | OFF State Voltage | Max 2.0 V (with a cable length of 5 m) | | | Leakage Current | Max. 500 μA | | | Safety Input | Approx. 1.5 mA × 2 | | Environmental | Protection Rating | IP65/IP67 (IEC60529), IP69K (ISO20653) | | | Operating Temp. | -20 °C to +55 °C (No freezing) | | | Vibration Resistance | 10 to 55 Hz, Double amplitude 3.0 mm, 5 min in X, Y, Z directions | | | Shock Resistance | 30 G in X, Y, Z directions, 6 times each axis | keyence gs-11pc manual

Turn off the power supply. Disconnect the M12 cordset and verify with a multimeter that OSSD 1 and OSSD 2 are not shorted to +24VDC, 0VDC, or each other. Restart the power supply. Issue 2: LED Stays Red Even When Guard is Closed Cause: Misalignment or incorrect actuator code tracking.

What or relay model are you connecting the outputs to?

18;write_to_target_document7;default0;998;18;write_to_target_document1a;_fpLuaaPXLJOMnesPsbvS-A8_20;a3; Key Specifications 0;16; 0;4f8;0;57e; Non-contact (magnet-based) Model: GS-11PC Operating Distance (Front):0;864;0;1026; Saocap S sub a o end-sub 0;aea; (OFF →right arrow 0;1323; ON): Sarcap S sub a r end-sub 0;ae9; (ON →right arrow 0;1324; OFF): Output: PNP transistor outputs Connection: M12 connector Cascading: Up to 30 units

When using the GS-11PC as a standalone unit (not cascaded), the OSSD inputs must be tied to +24 VDC to enable the outputs. Connect to +24 VDC. Connect Pin 7 (Blue) to 0 VDC. Connect Pin 4 (Yellow) and Pin 8 (Red) to +24 VDC. Are you dealing with an , wiring ,

The manual points to electromagnetic noise. Use a ferrite core (clamp filter) on the cable near the sensor head. Also, verify the shield (Pin 5) is grounded at only one end (controller side) to avoid ground loops.

These documents are available as free downloads directly from the Keyence website, though you will need to create a free account to access them. If a manual is not immediately available, you can contact Keyence's technical support directly, who can provide the latest official documents for your product.

Proper wiring is essential to ensure the safety circuit functions as intended. The GS-11PC uses a standard 8-pin M12 connector. 1. Wiring Pinout (PNP) +24 VDC. Blue: 0 V. White: OSSD 1 (Safety Output). Black: OSSD 2 (Safety Output). Grey: AUX Output (Non-safety, used for PLC monitoring). Pink: Reset/EDM Input. 2. Mounting the Actuator

For more specific information regarding your application, downloading the official Keyence GS-11PC instruction manual is recommended. The actuator can approach the switch from the

What are you currently trying to troubleshoot?

Requires 24V DC power. Unused wires should be independently insulated and not bundled.

Understanding the core electrical and mechanical attributes of the GS-11PC ensures safe integration into your machinery control systems.

Connect (AUX) to a standard PLC input card for HMI door status visualization. 4. Installation and Mounting Guidelines

The face of the GS-11PC features highly visible LED indicators to assist with alignment: